| Dimension |
81.5 (L) * 53.5 (W) * 42.5(H) mm max. |
Total output regulation |
5% |
| Weight |
180 g max. |
Line regulation |
2% at nominal input voltage and full load |
| Vout (normal) |
DC +18 V |
Ripple and noise |
1. 180 mVp-p max.
2. At 20 Mhz and output parallel with 0.1 uF & 47 uF capacitors to ground temperature at 25°C, and 115 VAC input voltage. |
| Minimum load current |
0 A |
Efficiency |
1. 65% minimum
2. At nominal input voltage and full load |
| Maximum load current |
1 A |
Drop-out |
1. With half cycle input voltage drop-out, the unit shall operate within the prescribed voltages with a drop-out pulse repetition rate of 500mS.
2. Conditions: Full load and nominal input AC voltage
3. Limits: Meet the regulation requirement. |
| Maximum output power |
18 W |
Short-circuit protection |
5W maximum with auto-recovery function |
| Input |
AC100V~240V |
Over-voltage protection |
26 VDC maximum with zener clamp |
| Output |
DC18V, 1 A |
Cirtificate |
CE, GS, UL approved |
| Unless otherwise specification output load must set at CR mode. |